ADC

Managing high availability heartbeat messages on a Citrix ADC appliance

The two nodes in a high availability configuration send and receive heartbeat messages to and from each other on all interfaces that are enabled. The heartbeat messages flow regardless of the HA MON setting on these interfaces. If NSVLAN or both (NSVLAN and SYNC) are configured on an appliance, the heartbeat messages flow only through the enabled interfaces that are part of the NSVLAN and SYNCVLAN.

If a node does not receive the heartbeat messages on an enabled interface, it sends critical alerts to the specified SNMP managers. These critical alerts give false alarms and draw unnecessary attention from the administrators for interfaces that are not configured as part of the connections to the peer node.

To resolve this issue, the HAHeartBeat option for interfaces and channels is used for enabling or disabling HA heartbeat-message flow on them.

To manage the high availability heartbeat messages on an interface by using the command line interface

At the command prompt, type:

  • set interface [-HAHeartBeat ( ON | OFF )]
  • show interface

To manage the high availability heartbeat messages on a channel by using the command line interface

At the command prompt, type:

  • set channel [-HAHeartBeat ( ON | OFF )]
  • show channel

To manage the high availability heartbeat messages for an interface by using the GUI

  1. Navigate toSystem>Network>Interfaces.
  2. Enable or disable theHA Heart Beatparameter.

To manage the high availability heartbeat messages on a channel by using the GUI

  1. Navigate toSystem>Network>Channels.
  2. Enable or disable theHA Heart Beatparameter.