Getting Started with Citrix ADC
Deploy a Citrix ADC VPX instance
安装Citrix ADCVPX instance on Linux-KVM platform
Prerequisites for Installing Citrix ADC VPX Virtual Appliances on Linux-KVM Platform
Provisioning the Citrix ADC Virtual Appliance by using OpenStack
Provisioning the Citrix ADC Virtual Appliance by using the Virtual Machine Manager
Configuring Citrix ADC Virtual Appliances to Use SR-IOV Network Interface
Configuring Citrix ADC Virtual Appliances to use PCI Passthrough Network Interface
Provisioning the Citrix ADC Virtual Appliance by using the virsh Program
Provisioning the Citrix ADC Virtual Appliance with SR-IOV, on OpenStack
Configuring a Citrix ADC VPX Instance on KVM to Use OVS DPDK-Based Host Interfaces
Deploy a Citrix ADC VPX instance on Microsoft Azure
Network architecture for Citrix ADC VPX instances on Microsoft Azure
Configure multiple IP addresses for a Citrix ADC VPX standalone instance
Configure a high-availability setup with multiple IP addresses and NICs
Configure a high-availability setup with multiple IP addresses and NICs by using PowerShell commands
Configure HA-INC nodes by using the Citrix high availability template with Azure ILB
Configure address pools (IIP) for a Citrix Gateway appliance
Upgrade and downgrade a Citrix ADC appliance
年代olutions for Telecom Service Providers
Load Balance Control-Plane Traffic that is based on Diameter, SIP, and SMPP Protocols
Provide Subscriber Load Distribution Using GSLB Across Core-Networks of a Telecom Service Provider
Authentication, authorization, and auditing application traffic
Configuring authentication, authorization, and auditing policies
Configuring Authentication, authorization, and auditing with commonly used protocols
Use an on-premises Citrix Gateway as the identity provider for Citrix Cloud
Troubleshoot authentication issues in Citrix ADC and Citrix Gateway with aaad.debug module
-
-
-
-
-
Persistence and persistent connections
Advanced load balancing settings
Gradually stepping up the load on a new service with virtual server–level slow start
Protect applications on protected servers against traffic surges
Retrieve location details from user IP address using geolocation database
Use source IP address of the client when connecting to the server
Use client source IP address for backend communication in a v4-v6 load balancing configuration
年代et a limit on number of requests per connection to the server
Configure automatic state transition based on percentage health of bound services
Use case 2: Configure rule based persistence based on a name-value pair in a TCP byte stream
Use case 3: Configure load balancing in direct server return mode
Use case 6: Configure load balancing in DSR mode for IPv6 networks by using the TOS field
Use case 7: Configure load balancing in DSR mode by using IP Over IP
Use case 10: Load balancing of intrusion detection system servers
Use case 11: Isolating network traffic using listen policies
Use case 12: Configure Citrix Virtual Desktops for load balancing
Use case 13: Configure Citrix Virtual Apps for load balancing
Use case 14: ShareFile wizard for load balancing Citrix ShareFile
-
-
-
-
-
Configuring SNMP Alarms for Rate Limiting
-
Configuring a CloudBridge Connector Tunnel between two Datacenters
Configuring CloudBridge Connector between Datacenter and AWS Cloud
Configuring a CloudBridge Connector Tunnel Between a Datacenter and Azure Cloud
Configuring CloudBridge Connector Tunnel between Datacenter and SoftLayer Enterprise Cloud
Configuring a CloudBridge Connector Tunnel Between a Citrix ADC Appliance and Cisco IOS Device
CloudBridge Connector Tunnel Diagnostics and Troubleshooting
This content has been machine translated dynamically.
Dieser Inhalt ist eine maschinelle Übersetzung, die dynamisch erstellt wurde.(Haftungsausschluss)
Cet article a été traduit automatiquement de manière dynamique.(Clause de non responsabilité)
Este artículo lo ha traducido una máquina de forma dinámica.(Aviso legal)
此内容已经过机器动态翻译。放弃
このコンテンツは動的に機械翻訳されています。免責事項
이 콘텐츠는 동적으로 기계 번역되었습니다.책임 부인
Este texto foi traduzido automaticamente.(Aviso legal)
Questo contenuto è stato tradotto dinamicamente con traduzione automatica.(Esclusione di responsabilità))
这篇文章已经被机器翻译。
Dieser Artikel wurde maschinell übersetzt.(Haftungsausschluss)
Ce article a été traduit automatiquement.(Clause de non responsabilité)
Este artículo ha sido traducido automáticamente.(Aviso legal)
この記事は機械翻訳されています.免責事項
이 기사는 기계 번역되었습니다.책임 부인
Este artigo foi traduzido automaticamente.(Aviso legal)
这篇文章已经过机器翻译.放弃
Questo articolo è stato tradotto automaticamente.(Esclusione di responsabilità))
Translation failed!
Configuring SNMP Alarms for rate limiting
Citrix ADC电器如Citrix ADC MPX 10500, 12500, and 15500 are rate limited. The maximum throughput (Mbps) and packets per second (PPS) are determined by the license purchased for the appliance. For rate-limited platforms, you can configure SNMP traps to send notifications when throughput and PPS approach their limits and when they return to normal.
Throughput and PPS are monitored every seven seconds. You can configure traps with high-threshold and normal-threshold values, which are expressed as a percentage of the licensed limits. The appliance then generates a trap when throughput or PPS exceeds the high threshold, and a second trap when the monitored parameter falls to the normal threshold. In addition to sending the traps to the configured destination device, the Citrix ADC logs the events associated with the traps in the /var/log/ns.log file as EVENT ALERTSTARTED and EVENT ALERTENDED.
Exceeding the throughput limit can result in packet loss. You can configure SNMP alarms to report packet loss.
For more information about SNMP alarms and traps, see “Configuring the Citrix ADC to generate SNMP v1 and v2 Traps.”
This document includes the following details:
- Configuring an SNMP Alarm for Throughput or PPS
- Configuring SNMP Alarm for Dropped Packets
Configuring an SNMP alarm for throughput or PPS
To monitor both throughput and PPS, you must configure seperate alarms and set threshold PPS value in Mbps.
To configure an SNMP alarm for the throughput rate by using the command line interface
At the command prompt, type the following commands to configure the SNMP alarm, set threshold value in Mbps and verify the configuration:
set snmp alarm PF-RL-RATE-THRESHOLD [-thresholdValue
[-normalValue ]] [-state ( **ENABLED** | **DISABLED** )] [-severity ] [-logging ( **ENABLED** | **DISABLED** )] show snmp alarm PF-RL-RATE-THRESHOLD
Example
> set snmp alarm PF-RL-RATE-THRESHOLD -thresholdValue 70 -normalValue 50
To configure an SNMP alarm for PPS by using the command line interface
At the command prompt, type the following commands to configure the SNMP alarm for PPS and verify the configuration:
set snmp alarm PF-RL-PPS-THRESHOLD [-thresholdValue
[-normalValue ]] [-state ( **ENABLED** | **DISABLED** )] [-severity ] [-logging ( **ENABLED** | **DISABLED** )] show snmp alarm PF-RL-PPS-THRESHOLD
Example
> set snmp alarm PF-RL-PPS-THRESHOLD -thresholdValue 70 -normalValue 50
To configure an SNMP alarm for throughput or PPS by using the GUI
- Navigate to年代ystem>年代NMP>Alarms, and selectPF-RL-RATE-THRESHOLD(for throughput rate) orPF-RL-PPS-THRESHOLD(for packets per second).
- 年代et the alarm parameters and enable the selected SNMP alarm.
Configuring SNMP alarm for dropped packets
You can configure an alarm for packets dropped as a result of exceeding the throughput limit and an alarm for packets dropped as a result of exceeding the PPS limit.
为包配置SNMP警报bec下降ause of excessive throughput, by using the command line interface
At the command prompt, type:
set snmp alarm PF-RL-RATE-PKTS-DROPPED [-state (ENABLED | DISABLED)] [-severity
为包配置SNMP警报bec下降ause of excessive PPS, by using the command line interface
At the command prompt, type:
set snmp alarm PF-RL-PPS-PKTS-DROPPED [-state (ENABLED | DISABLED)] [-severity
To configure an SNMP alarm for dropped packets by using the GUI
- Navigate to年代ystem>年代NMP>Alarms, and selectPF-RL-RATE-PKTS-DROPPED(for packets dropped because of excessive throughput) orPF-RL-PPS-PKTS-DROPPED(for packets dropped because of excessive PPS).
- 年代et the alarm parameters and enable the selected SNMP alarm.
年代hare
年代hare
This Preview product documentation is Citrix Confidential.
You agree to hold this documentation confidential pursuant to the terms of your Citrix Beta/Tech Preview Agreement.
The development, release and timing of any features or functionality described in the Preview documentation remains at our sole discretion and are subject to change without notice or consultation.
The documentation is for informational purposes only and is not a commitment, promise or legal obligation to deliver any material, code or functionality and should not be relied upon in making Citrix product purchase decisions.
If you do not agree, select Do Not Agree to exit.